Puretratech · P-PT89KCSTCF

Double-Layer Hydrophobic PTFE Sterilizing-Grade Capsule Filter — Pharmaceutical processing and Antibiotic-process venting

Double-Layer Hydrophobic PTFE Sterilizing-Grade Capsule Filter for Pharmaceutical processing and Antibiotic-process venting. Its construction, retention rating and operating limits are the same as the base model PT89KCSTCF.

Application field: PSterilizing grade: Yes
Request a quote
SKU / ModelP-PT89KCSTCF
MOQ12 pcs
Lead time20 days
Country of originChina
HS code8421999090
Support / warranty3 years

01 / 09

PRODUCT OVERVIEW

Double-Layer Hydrophobic PTFE Sterilizing-Grade Capsule Filter for Pharmaceutical processing and Antibiotic-process venting. Its construction, retention rating and operating limits are the same as the base model PT89KCSTCF.

If you are considering this product for Pharmaceutical processing and Antibiotic-process venting, confirm process-fluid compatibility, retention rating, operating conditions and any sterilization or sanitization requirements before ordering.

This full-size capsule filter incorporates a Stäubli vent connection for online integrity testing and robust process validation.

Its double-layer hydrophobic PTFE membrane provides excellent chemical compatibility and high flow per unit area for corrosive and critical gas applications.

02 / 09

KEY FEATURES

  • Double-layer hydrophobic PTFE membrane
  • Stäubli vent connection for online integrity testing
  • Broad chemical resistance
  • High gas flow per unit area
  • 100% pre-shipment integrity tested
  • Sterilizing-grade particle and microorganism retention

03 / 09

APPLICATIONS

  • Pharmaceutical processing
  • Antibiotic-process venting

04 / 09

MATERIALS

ComponentMaterial / method
Filter membraneDouble-layer polytetrafluoroethylene (PTFE)
Media supportPolypropylene (PP)
End capsPolypropylene (PP)
Inner corePolypropylene (PP)
Outer cagePolypropylene (PP)

05 / 09

BIOLOGICAL SAFETY

All materials meet the biological-safety requirements of USP Class VI at 121 °C for plastics.

06 / 09

FOOD SAFETY COMPLIANCE

Materials of construction comply with FDA regulations for food and beverage contact use, as detailed in Title 21 of the U.S. Code of Federal Regulations (21 CFR). Materials used to produce the filter media and hardware are safe for use in contact with foodstuffs in accordance with EU 10/2011.

07 / 09

CAPSULE INTEGRITY

Minimum burst pressure: 123.5 psi (8.5 barg)

08 / 09

Integrity Test

Test parameterSpecification
Pore size0.2 µm
Bubble point≥ 1.4 barg (IPA/Water)
Water intrusion≤ 0.37 ml/min @ 2500 mbar/10", 22 °C

09 / 09

Product Configuration / Ordering Information

Product number / modelPore sizeLengthFittingsVentDrain
P-PT89KCSTCF0021=0.2/0.1µm03=2.5"1HT=1.5" TCS=StäubliS=Stäubli
0022=0.2/0.2µm05=5"MT=0.5" TCH=Hose BarbH=Hose Barb
10=10"08H=1/2" Hose Barb
20=20"12H=3/4" Hose Barb
30=30"8N=1/2" NPT
40=40"8NF=1/2" NPT-F