Puretratech · P-PT69SPBRMS

Sterilizing-Grade PES Membrane Filter Cartridge — Cell culture media and Large-volume parenterals (LVPs)

Sterilizing-Grade PES Membrane Filter Cartridge for Cell culture media and Large-volume parenterals (LVPs). Its construction, retention rating and operating limits are the same as the base model PT69SPBRMS.

Application field: PSterilizing grade: Yes
Request a quote
SKU / ModelP-PT69SPBRMS
MOQ12 pcs
Lead time20 days
Country of originChina
HS code8421999090
Support / warranty3 years

01 / 09

PRODUCT OVERVIEW

Sterilizing-Grade PES Membrane Filter Cartridge for Cell culture media and Large-volume parenterals (LVPs). Its construction, retention rating and operating limits are the same as the base model PT69SPBRMS.

If you are considering this product for Cell culture media and Large-volume parenterals (LVPs), confirm process-fluid compatibility, retention rating, operating conditions and any sterilization or sanitization requirements before ordering.

These bioburden-reduction polyethersulfone (PES) membrane filter cartridges are engineered to achieve product-level sterility.

The filters feature a single-layer hydrophilic PES membrane with an all-polypropylene component construction. They deliver broad chemical compatibility, high flow rates with low pressure drop, and minimal extractables.

02 / 09

KEY FEATURES

  • Hydrophilic asymmetric PES membrane
  • Low protein binding
  • Broad chemical compatibility
  • High flow with low pressure drop
  • Minimal extractables
  • All-polypropylene component construction

03 / 09

APPLICATIONS

  • Cell culture media
  • Large-volume parenterals (LVPs)

04 / 09

MATERIALS

ComponentMaterial / method
Filter membranePolyethersulfone (PES)
Media supportPolypropylene (PP)
End capsPolypropylene (PP)
Inner corePolypropylene (PP)
Outer cagePolypropylene (PP)
Sealing methodThermal bonding
O-ringsBuna-N, Viton/FKM, EP, Silicone, encapsulated Silicone or encapsulated Viton/FKM

05 / 09

BIOLOGICAL SAFETY

All components meet the biological-safety requirements of USP Class VI at 121 °C for plastics.

06 / 09

MAXIMUM OPERATING PARAMETERS

  • Forward differential pressure: 50 psid (3.4 barg) at 20 °C (68 °F)
  • Reverse differential pressure: 40 psid (2.7 barg) at 20 °C (68 °F)
  • Operating temperature: 82 °C (180 °F) at 10 psid (0.69 barg) in water
  • Recommended change-out pressure: 35 psid (2.4 barg)

07 / 09

SANITIZATION / STERILIZATION

  • Filtered hot water: 90 °C (194 °F), 30 minutes, multiple cycles; maximum 3 psid forward flow
  • Autoclave: 121 °C (250 °F), 30 minutes, multiple cycles
  • In-line steam: 135 °C (275 °F), 30 minutes, multiple cycles

08 / 09

Integrity Test

Pore sizeMinimum bubble point
0.04 µm31.9 PSI / 2.2 barg (IPA)
0.1 µm24.7 PSI / 1.7 barg (IPA)
0.2 µm51 PSI / 3.5 barg
0.45 µm35 PSI / 2.4 barg
0.65 µm22 PSI / 1.5 barg

09 / 09

Product Configuration / Ordering Information

Product number / modelPore sizeLengthEndcapsSealConnection support
P-PT69SPBRMS0x4=0.04µm05=5 inch7=226/finB=Buna-NS=SS reinforcement
001=0.1µm10=10 inch6=226/flatE=EPDM
002=0.2µm20=20 inch0=222/flatS=Silicone
004=0.45µm30=30 inch5=222/finV=Viton
006=0.65µm40=40 inchF=DOE
2=224/fin
3=224/flat
4=222/fin (3 lugs)
8=222/flat (3 lugs)
x=213 internal O-ring