Puretratech · P-PT56SPGAJN

Hydrophilic Nylon 66 Pleated Filter Cartridge — Pharmaceutical intermediates

Hydrophilic Nylon 66 Pleated Filter Cartridge for Pharmaceutical intermediates. Its construction, retention rating and operating limits are the same as the base model PT56SPGAJN.

Application field: PSterilizing grade: No
Request a quote
SKU / ModelP-PT56SPGAJN
MOQ12 pcs
Lead time10 days
Country of originChina
HS code8421999090
Support / warranty3 years

01 / 10

PRODUCT OVERVIEW

Hydrophilic Nylon 66 Pleated Filter Cartridge for Pharmaceutical intermediates. Its construction, retention rating and operating limits are the same as the base model PT56SPGAJN.

If you are considering this product for Pharmaceutical intermediates, confirm process-fluid compatibility, retention rating, operating conditions and any sterilization or sanitization requirements before ordering.

Pleated filter cartridges featuring a Nylon 66 membrane undergo rigorous 100% factory integrity testing to ensure reliable fine-particle and microorganism retention in critical processing environments.

Constructed with a high-purity single-layer hydrophilic Nylon 66 membrane, this cartridge requires no pre-wetting agents, eliminating surfactant leaching into sensitive process streams.

02 / 10

KEY FEATURES

  • Naturally Hydrophilic Nylon 66: Eliminates the need for pre-wetting agents or surfactants, ensuring instant wetted performance and ultra-low extractables.
  • 100% Factory Integrity Tested: Verified via bubble point test to ensure absolute structural integrity and precise sub-micron particulate control.
  • Enhanced Zeta Potential Adsorption: Natural membrane charge assists in capturing fine particulates, trace endotoxins, and negatively charged impurities.
  • Superior Alkaline & Solvent Resistance: Excellent chemical compatibility with alcohols, hydrocarbons, and high-pH alkaline cleaning solutions.
  • Space-Saving Mini Pleated Design: High packing density maximizes filtration surface area for low differential pressure and high throughput in small housings.

03 / 10

APPLICATIONS

  • Pharmaceutical intermediates

04 / 10

MATERIALS

ComponentMaterial / method
Filter membraneNylon66
Media supportPolypropylene
End capsPolypropylene with embedded 316 ring
Inner corePP / SUS 316L perforated core
Outer cagePolypropylene
Sealing methodThermal bonding
O-ringsBuna, Viton (or FKM), EP, Silicone, Encapsulated Silicone, Encapsulated Viton (or FKM)

05 / 10

BIOLOGICAL SAFETY

All components meet the specifications for biological safety per USP Class VI at 121 °C for plastics.

06 / 10

FOOD SAFETY COMPLIANCE

Materials of construction comply with FDA regulations for food and beverage contact use as detailed in the US Code of Federal Regulations, Title 21 of the U.S. Code of Federal Regulations (21 CFR). Materials used to produce filter media and hardware are safe for use in contact with foodstuffs in accordance with EU 10/2011.

07 / 10

MAXIMUM OPERATING PARAMETERS

  • Forward differential pressure: 50 psid (3.4 barg) at 20 °C (68 °F)
  • Reverse differential pressure: 40 psid (2.7 barg) at 20 °C (68 °F)
  • Operating temperature: 82 °C (180 °F) at 10 psid (0.69 barg) in water
  • Recommended change-out pressure: 35 psid (2.4 barg)

08 / 10

SANITIZATION / STERILIZATION

  • Filtered hot water: 90 °C (194 °F), 30 minutes, multiple cycles; maximum 3 psid forward flow
  • Autoclave: 121 °C (250 °F), 30 minutes, multiple cycles
  • In-line steam: 135 °C (275 °F), 30 minutes, multiple cycles

09 / 10

Integrity Test

Pore sizeMinimum bubble point
0.1 µm50.8 psig (3.5 bar)
0.2 µm40.6 psig (2.8 bar)
0.45 µm26.1 psig (1.8 bar)
0.65 µm16 psig (1.1 bar)
1.0 µm8.7 psig (0.6 bar)

10 / 10

Product Configuration / Ordering Information

Product number / modelPore sizeAreaEndcapsSealConnection support
P-PT56SPGAJN001=0.1µmH=500 cm²A=116 without locking grooveB=Buna-NS=Stainless-steel reinforcement
002=0.2µmS=1000 cm²B=116 with locking grooveE=EPDM
004=0.45µmD=1500 cm²C=116 with locking groove and stainless-steel ringS=Silicone
006=0.65µmL=2100 cm²D=118 double O-ringV=Viton/FKM
010=1.0µmE=118 with short lugs (Pall replacement)
F=118 with long lugs (Sartorius replacement)
G=1/2-inch NPT threaded
H=123 double O-ring
I=126 double O-ring
J=1-inch TC
K=80 mm skirt
L=1/2-inch TC
M=1/2-inch BSPT
N=123 double O-ring
O=AS116 (Pall replacement)
P=AS116 (Parker replacement)
Q=1/2-inch BSPP
R=Optiseal LAGR compatible