Puretratech · PT89KCSTCV

Double-Layer Hydrophilic PVDF Sterilizing-Grade Capsule Filter

Double-layer hydrophilic PVDF capsule filter with adhesive-free construction, high flow and low extractables for validated aqueous bioprocess filtration.

Sterilizing grade: YesSource verifiedEnglish source
Request a quote
Puretratech PT89KCSTCV 89 mm Capsule Filters
MODELPT89KCSTCVFORMAT89 mm Capsule Filters
SKU / ModelPT89KCSTCV
MOQ12 pcs
Lead time20 days
Country of originChina
HS code8421999090
Support / warranty3 years

01 / 09

PRODUCT OVERVIEW

Designed for low-binding, high-value fluid filtration

This full-size capsule filter incorporates a Stäubli vent connection for online integrity testing in regulatory-oriented biopharmaceutical workflows.

Its double-layer hydrophilic PVDF membrane provides reliable retention, broad chemical compatibility, high flow and low extractables in aqueous process fluids.

The adhesive-, binder- and surfactant-free construction is rinsed with high-purity water to improve downstream cleanliness and reduce batch downtime.

02 / 09

KEY FEATURES

Construction and performance

  • Double-layer hydrophilic PVDF membrane
  • Reliable retention in aqueous process fluids
  • Adhesive-, binder- and surfactant-free construction
  • High flow and low extractables
  • High-purity-water rinsed
  • Online integrity-testable Stäubli vent

03 / 09

APPLICATIONS

Typical process uses

  • Beverages
  • Fine chemicals
  • Pharmaceutical processing
  • Gas filtration
  • Biological processing
  • Antibiotic processing
  • Serum processing

04 / 09

MATERIALS

Materials of construction

Structured text sourced from the submitted workbook.

ComponentMaterial / method
Filter membraneDouble-layer hydrophilic polyvinylidene fluoride (PVDF)
Media supportPolypropylene (PP)
End capsPolypropylene (PP)
Inner corePolypropylene (PP)
Outer cagePolypropylene (PP)

05 / 09

BIOLOGICAL SAFETY

All materials meet the biological-safety requirements of USP Class VI at 121 °C for plastics.

06 / 09

FOOD SAFETY COMPLIANCE

Materials of construction comply with FDA regulations for food and beverage contact use, as detailed in Title 21 of the U.S. Code of Federal Regulations (21 CFR). Materials used to produce the filter media and hardware are safe for use in contact with foodstuffs in accordance with EU 10/2011.

07 / 09

CAPSULE INTEGRITY

Minimum burst pressure: 123.5 psi (8.5 barg)

08 / 09

Integrity Test

Minimum bubble point by pore size. Values are transcribed from the submitted image.

Pore sizeBubble point
0.2/0.2 µm3.8 barg @ 20 °C
0.65/0.45 µm2.1 barg @ 20 °C

09 / 09

Product Configuration / Ordering Information

The table uses one dynamic column per code segment and one “company code=product meaning” expression per option. Row count follows the longest column.

Series codePore sizeLengthFittingsVentDrain
KCSTCV0022=0.2/0.2µm03=2.5"1HT=1.5" TCS=StäubliS=Stäubli
0064=0.65/0.45µm05=5"MT=0.5" TCH=Hose BarbH=Hose Barb
10=10"08H=1/2" Hose Barb
20=20"12H=3/4" Hose Barb
30=30"8N=1/2" NPT
40=40"8NF=1/2" NPT-F