Puretratech · PT89KCSTCF

Double-Layer Hydrophobic PTFE Sterilizing-Grade Capsule Filter

Double-layer hydrophobic PTFE capsule filter with online integrity testing, broad chemical resistance and high gas flow for critical sterile gas processes.

Sterilizing grade: YesSource verifiedEnglish source
Request a quote
Puretratech PT89KCSTCF 89 mm Capsule Filters
MODELPT89KCSTCFFORMAT89 mm Capsule Filters
SKU / ModelPT89KCSTCF
MOQ12 pcs
Lead time20 days
Country of originChina
HS code8421999090
Support / warranty3 years

01 / 09

PRODUCT OVERVIEW

Designed for low-binding, high-value fluid filtration

This full-size capsule filter incorporates a Stäubli vent connection for online integrity testing and robust process validation.

Its double-layer hydrophobic PTFE membrane provides excellent chemical compatibility and high flow per unit area for corrosive and critical gas applications.

Every filter is integrity tested before shipment to provide reliable and repeatable out-of-package performance where stringent particle and microorganism removal is required.

02 / 09

KEY FEATURES

Construction and performance

  • Double-layer hydrophobic PTFE membrane
  • Stäubli vent connection for online integrity testing
  • Broad chemical resistance
  • High gas flow per unit area
  • 100% pre-shipment integrity tested
  • Sterilizing-grade particle and microorganism retention

03 / 09

APPLICATIONS

Typical process uses

  • Fermentation tanks
  • Bioprocess bags
  • Pharmaceutical processing
  • Gas filtration
  • Biological processing
  • Antibiotic-process venting
  • Serum processing

04 / 09

MATERIALS

Materials of construction

Structured text sourced from the submitted workbook.

ComponentMaterial / method
Filter membraneDouble-layer polytetrafluoroethylene (PTFE)
Media supportPolypropylene (PP)
End capsPolypropylene (PP)
Inner corePolypropylene (PP)
Outer cagePolypropylene (PP)

05 / 09

BIOLOGICAL SAFETY

All materials meet the biological-safety requirements of USP Class VI at 121 °C for plastics.

06 / 09

FOOD SAFETY COMPLIANCE

Materials of construction comply with FDA regulations for food and beverage contact use, as detailed in Title 21 of the U.S. Code of Federal Regulations (21 CFR). Materials used to produce the filter media and hardware are safe for use in contact with foodstuffs in accordance with EU 10/2011.

07 / 09

CAPSULE INTEGRITY

Minimum burst pressure: 123.5 psi (8.5 barg)

08 / 09

Integrity Test

Minimum bubble point by pore size. Values are transcribed from the submitted image.

Test parameterSpecification
Pore size0.2 µm
Bubble point≥ 1.4 barg (IPA/Water)
Water intrusion≤ 0.37 ml/min @ 2500 mbar/10", 22 °C

09 / 09

Product Configuration / Ordering Information

The table uses one dynamic column per code segment and one “company code=product meaning” expression per option. Row count follows the longest column.

Series codePore sizeLengthFittingsVentDrain
KCSTCF0021=0.2/0.1µm03=2.5"1HT=1.5" TCS=StäubliS=Stäubli
0022=0.2/0.2µm05=5"MT=0.5" TCH=Hose BarbH=Hose Barb
10=10"08H=1/2" Hose Barb
20=20"12H=3/4" Hose Barb
30=30"8N=1/2" NPT
40=40"8NF=1/2" NPT-F