Puretratech · PT89KCBRCF

Hydrophobic PTFE Sterilizing-Grade Capsule Filter for Bacterial Retention

High-flow hydrophobic PTFE capsule filter with a Stäubli vent connection and 100% pre-shipment integrity testing for critical sterile gas filtration.

Sterilizing grade: YesSource verifiedEnglish source
Request a quote
Puretratech PT89KCBRCF 89 mm Capsule Filters
MODELPT89KCBRCFFORMAT89 mm Capsule Filters
SKU / ModelPT89KCBRCF
MOQ12 pcs
Lead time20 days
Country of originChina
HS code8421999090
Support / warranty3 years

01 / 09

PRODUCT OVERVIEW

Designed for low-binding, high-value fluid filtration

This full-size capsule filter features a Stäubli vent connection that enables online integrity testing for process safety.

The hydrophobic PTFE membrane provides excellent chemical compatibility and high flow per unit area across a wide range of gas-phase applications.

Every filter is integrity tested before shipment to support consistent out-of-package performance in critical particle- and microorganism-removal applications.

02 / 09

KEY FEATURES

Construction and performance

  • Full-size capsule filter with Stäubli vent connection
  • Online integrity testing for process safety
  • Hydrophobic PTFE membrane with broad chemical compatibility
  • High gas flow per unit area
  • 100% pre-shipment integrity tested
  • High particle and microorganism removal for critical gas applications

03 / 09

APPLICATIONS

Typical process uses

  • Fermentation tanks
  • Bioprocess bags
  • Pharmaceutical processing
  • Gas filtration
  • Biological processing
  • Antibiotic-process venting
  • Serum processing

04 / 09

MATERIALS

Materials of construction

Structured text sourced from the submitted workbook.

ComponentMaterial / method
Filter membranePolytetrafluoroethylene (PTFE)
Media supportPolypropylene (PP)
End capsPolypropylene (PP)
Inner corePolypropylene (PP)
Outer cagePolypropylene (PP)

05 / 09

BIOLOGICAL SAFETY

All materials meet the biological-safety requirements of USP Class VI at 121 °C for plastics.

06 / 09

FOOD SAFETY COMPLIANCE

Materials of construction comply with FDA regulations for food and beverage contact use, as detailed in Title 21 of the U.S. Code of Federal Regulations (21 CFR). Materials used to produce the filter media and hardware are safe for use in contact with foodstuffs in accordance with EU 10/2011.

07 / 09

CAPSULE INTEGRITY

Minimum burst pressure: 123.5 psi (8.5 barg)

08 / 09

Integrity Test

Minimum bubble point by pore size. Values are transcribed from the submitted image.

Test parameterSpecification
Pore size0.2 µm
Bubble point≥ 1.4 barg (IPA/Water)
Water intrusion≤ 0.37 ml/min @ 2500 mbar/10", 22 °C

09 / 09

Product Configuration / Ordering Information

The table uses one dynamic column per code segment and one “company code=product meaning” expression per option. Row count follows the longest column.

Series codePore sizeLengthFittingsVentDrain
KCBRCF001=0.1µm03=2.5"1HT=1.5" TCS=StäubliS=Stäubli
002=0.2µm05=5"MT=1/2" TCH=Hose BarbH=Hose Barb
10=10"08H=1/2" Hose Barb
20=20"12H=3/4" Hose Barb
30=30"8N=1/2" NPT
40=40"8NF=1/2" NPT-F